Form I Part B: Certificate of inspection for shop assembled boilers
The Inspecting Authority's certificate that a shop-assembled boiler was built under its supervision, inspected at each stage and hydrostatically tested.
Pujan Motiwala · Checked against the Gazette on · IBR 2026, in force from 1 October 2026
What is Form I Part B?
Form I Part B of the Indian Boiler Regulations, 2026 is the certificate of inspection for shop assembled boilers, prescribed under regulation 8(a). Under the Indian Boiler Regulations, 1950 it was Form II(1) (certificate of inspection for shop assembled boilers).
Who issues and signs Form I Part B?
The Inspecting Authority, signed by its Competent Person and the Inspecting Authority, with date and seal.
What does Form I Part B record?
- The boiler type, maker and maker's number
- That it was built under supervision and inspected at stages by the Competent Person
- The stamp on the shell plate: maker's name and number, year of make, test pressure and date, design pressure in kg/cm² (g)
- The hydrostatic test pressure and the date it was witnessed
- That welded seams passed destructive and non-destructive examination where applicable
- The maker's drawing number, and that Form IV Part A was countersigned
When is Form I Part B filed, and with what?
Goes to the Chief Inspector with the registration application, alongside Form IV Part A, the drawings and the material certificates (regulation 8).
What changed for Form I Part B from IBR 1950?
Under IBR 1950 this was Form II(1). The wording is nearly the same; the stamp now shows the design pressure where the 1950 form showed the working pressure (W.P.), and the form refers to the Boilers Act, 2025 and to Form IV Part A instead of Form III.
Related forms
- Form I Part A: Inspecting Authority's certificate of inspection during construction, boiler made to a foreign code for export (was Form II-A)
- Form I Part C: Certificate of inspection for site assembled boilers at maker's works (was Form II(2))
- Form I Part D: Inspecting Authority's certificate of inspection during construction of boilers with permitted variations from standard conditions (was Form II-B)
- Form I Part E: Inspecting Authority's certificate of inspection after completion of boiler erection at assembly site (was Form II-C)
- Form VIII: Final inspection report for boiler components
Quoted from the regulations (3)
“A certificate in Form-I(Part-B) or Form-I(Part-C), as the case may be, from an Inspecting Authority, certifying that the material was tested and the boiler was built under their supervision”
IBR 2026, regulation 8(a)(i)
“was constructed under our supervision and inspected at various stages of construction by the Competent Person”
IBR 2026, Form I Part B
“All welded seams were subjected to destructive and Non-Destructive examination wherever applicable and found satisfactory.”
IBR 2026, Form I Part B
See a boiler's IBR folder produced from its material certificates, with a sample company.
Built for a boiler manufacturer: ERP for boiler manufacturers · how the folder is produced
Official sources
- Indian Boiler Regulations, 2026 (Gazette of India, Extraordinary, No. 596). Central Boilers Board, Department for Promotion of Industry and Internal Trade, October 1, 2026.
What this page is not
A guide written by Ahrom Labs from the Gazette text; not legal advice. The Gazette governs wherever this page differs from it, and a state's Chief Inspector of Boilers may set procedures of their own. Last updated .