Form XIII: Questionnaire for repairers of boilers, economisers, steam lines and feed water lines

The questionnaire a firm sends to the state's Chief Inspector of Boilers to be recognised as a boiler repairer (regulation 316(2)).

Pujan Motiwala · Checked against the Gazette on · IBR 2026, in force from 1 October 2026

What is Form XIII?

Form XIII of the Indian Boiler Regulations, 2026 is the questionnaire for repairers of boilers, economisers, steam lines and feed water lines, prescribed under regulation 316(2). Under the Indian Boiler Regulations, 1950 it was Form XVIII (questionnaire form for repairer of boilers/economizer/steam line/feed water lines).

Download Form XIII as a PDF: the form as notified, cut from the Gazette of India (No. 596, 1 October 2026) with nothing changed.

Who issues and signs Form XIII?

The firm applying for recognition as a repairer of boilers, economisers, steam lines and feed water lines.

What does Form XIII record?

  • Name, workshop address and year of establishment
  • Class applied for: Special Class (any pressure), Class I (up to 125 kg/cm²), Class II (up to 40 kg/cm²), Class III (up to 17.5 kg/cm²)
  • Jobs done before, with pressures, temperatures and materials
  • Tools: rectifier or generator, grinder, dye penetrant kit, expander and measuring instruments
  • Technical staff, welders with current IBR certificates, and the internal quality control system

When is Form XIII filed, and with what?

The Chief Inspector of Boilers of the State where the firm wants recognition.

What changed for Form XIII from IBR 1950?

Under IBR 1950 this was Form XVIII. Recognition lasts two years; a repairer found violating the Act or Regulations is blacklisted and not renewed.

  • Form IX: Details to be furnished with an application for inspection of a boiler after twelve or thirty-six months of certification (was Form XIX)
Quoted from the regulations (3)

“Any firm seeking recognition shall apply in 'Form-XIII' to the Chief Inspector of Boilers of the State”

IBR 2026, regulation 316(2)

“Class I (For Boiler Pressure upto 125 kg/cm2)”

IBR 2026, Form XIII

“The recognition of the firm as a repairer shall be for a period of two years”

IBR 2026, Form XIII, note 1

One email when the regulation or a form changes. No newsletter; reply “stop” any time.

See a boiler's IBR folder produced from its material certificates, with a sample company.

Free. Resets every night.

Built for a boiler manufacturer: ERP for boiler manufacturers · how the folder is produced · other rules an ERP must meet

Official sources

What this page is not

A guide written by Ahrom Labs from the Gazette text; not legal advice. The Gazette governs wherever this page differs from it, and a state's Chief Inspector of Boilers may set procedures of their own. Last updated .

Talk to us about your systems.

Tell us what's held together with workarounds right now. We reply to every message ourselves.