Form IV Part H: Certificate of manufacture and test for dished ends and end covers
The certificate for dished ends and end covers.
Pujan Motiwala · Checked against the Gazette on · IBR 2026, in force from 1 October 2026
What is Form IV Part H?
Form IV Part H of the Indian Boiler Regulations, 2026 is the certificate of manufacture and test for dished ends and end covers, prescribed under regulation 16. Under the Indian Boiler Regulations, 1950 it was Form III-I (certificate of manufacture and test for dished ends/end covers).
Download Form IV Part H as a PDF: the form as notified, cut from the Gazette of India (No. 596, 1 October 2026) with nothing changed.
Who issues and signs Form IV Part H?
The maker of the dished end or end cover and the Inspecting Authority.
What does Form IV Part H record?
- Name of the part, maker, customer and drawing number
- Maximum allowable working pressure, design temperature, heat treatment, hydraulic test pressure and non-destructive testing
- Raw material test certificates enclosed, or Form V Part B in lieu
- For each plate or forging: material specification, size, quantity, melt number or plate number, and test certificate number and date
- The final inspection date and the Competent Person's and Inspecting Authority's signatures
When is Form IV Part H filed, and with what?
Supplied with the dished ends to the boiler maker, and kept with the boiler's records (regulation 308).
What changed for Form IV Part H from IBR 1950?
Under IBR 1950 this was Form III-I. Dished ends bought from a pressing shop come with this form and the plate's own certificate.
Related forms
- Form IV Part A: Constructor's certificate of manufacture and test (was Form III)
- Form IV Part B: Certificate of manufacture and test for pipes (was Form III-A)
- Form IV Part C: Certificate of manufacture and test for tubes (was Form III-B)
- Form IV Part D: Certificate of manufacture and test of boiler mountings and fittings (was Form III-C)
- Form IV Part E: Certificate of manufacture and test of castings (was Form III-F)
- Form IV Part F: Certificate of manufacture and test of forgings (was Form III-G)
- Form IV Part G: Certificate of manufacture and test for headers, desuperheaters/attemperators, blowdown tanks, feed water tanks, accumulators and deaerators (was Form III-H)
- Form XXII: Certificate of manufacture and test for small industrial boilers (was Form XVII)
- Form XXIII: Certificate of manufacture and test for small solar boilers (was Form XVII)
Quoted from the regulations (2)
“Certificate of inspection during manufacture of dished ends or end covers.”
IBR 2026, regulation 16
“and test in Form-IV(Part-H), signed by the maker and the Inspecting Authority shall be furnished.”
IBR 2026, regulation 16
See a boiler's IBR folder produced from its material certificates, with a sample company.
Built for a boiler manufacturer: ERP for boiler manufacturers · how the folder is produced · other rules an ERP must meet
Official sources
- Indian Boiler Regulations, 2026 (Gazette of India, Extraordinary, No. 596). Central Boilers Board, Department for Promotion of Industry and Internal Trade, October 1, 2026.
What this page is not
A guide written by Ahrom Labs from the Gazette text; not legal advice. The Gazette governs wherever this page differs from it, and a state's Chief Inspector of Boilers may set procedures of their own. Last updated .
Talk to us about your systems.
Tell us what's held together with workarounds right now. We reply to every message ourselves.