Form IV Part G: Certificate of manufacture and test for headers, desuperheaters/attemperators, blowdown tanks, feed water tanks, accumulators and deaerators

The certificate for headers and similar standalone pressure parts, such as a steam header.

Pujan Motiwala · Checked against the Gazette on · IBR 2026, in force from 1 October 2026

What is Form IV Part G?

Form IV Part G of the Indian Boiler Regulations, 2026 is the certificate of manufacture and test for headers, desuperheaters/attemperators, blowdown tanks, feed water tanks, accumulators and deaerators, prescribed under regulation 15. Under the Indian Boiler Regulations, 1950 it was Form III-H (certificate of manufacture and test for headers, desuperheaters/attemperator, blowdown tank, feed water tanks, accumulator, deaerator).

Download Form IV Part G as a PDF: the form as notified, cut from the Gazette of India (No. 596, 1 October 2026) with nothing changed.

Who issues and signs Form IV Part G?

The maker of the part and the Inspecting Authority.

What does Form IV Part G record?

  • Name of the part, maker, customer and drawing number
  • Maximum allowable working pressure, design temperature, heat treatment, hydraulic test pressure and non-destructive testing
  • Raw material: refers to the enclosed material test certificates, or Form V Part B in lieu
  • A table of items (pipe, end cover, stubs, branch pipes) with material, size, quantity and melt number
  • The maker's certificate of the water test, the final inspection date, and the Competent Person's and Inspecting Authority's signatures

When is Form IV Part G filed, and with what?

Supplied with the part to the boiler maker or owner, and kept with the boiler's records (regulation 308).

What changed for Form IV Part G from IBR 1950?

New as a separate certificate in IBR 2026: headers, desuperheaters or attemperators, blowdown tanks, feedwater tanks, accumulators and deaerators each have one form.

  • Form IV Part A: Constructor's certificate of manufacture and test (was Form III)
  • Form IV Part B: Certificate of manufacture and test for pipes (was Form III-A)
  • Form IV Part C: Certificate of manufacture and test for tubes (was Form III-B)
  • Form IV Part D: Certificate of manufacture and test of boiler mountings and fittings (was Form III-C)
  • Form IV Part E: Certificate of manufacture and test of castings (was Form III-F)
  • Form IV Part F: Certificate of manufacture and test of forgings (was Form III-G)
  • Form IV Part H: Certificate of manufacture and test for dished ends and end covers (was Form III-I)
  • Form XXII: Certificate of manufacture and test for small industrial boilers (was Form XVII)
  • Form XXIII: Certificate of manufacture and test for small solar boilers (was Form XVII)
Quoted from the regulations (2)

“Certificate of inspection during manufacture of Headers, Desuperheaters or Attemperators, Blowdown Tanks, Feedwater Tanks, Accumulators and Dearators.”

IBR 2026, regulation 15

“signed by the maker and the Inspecting Authority, shall be furnished.”

IBR 2026, regulation 15

One email when the regulation or a form changes. No newsletter; reply “stop” any time.

See a boiler's IBR folder produced from its material certificates, with a sample company.

Free. Resets every night.

Built for a boiler manufacturer: ERP for boiler manufacturers · how the folder is produced · other rules an ERP must meet

Official sources

What this page is not

A guide written by Ahrom Labs from the Gazette text; not legal advice. The Gazette governs wherever this page differs from it, and a state's Chief Inspector of Boilers may set procedures of their own. Last updated .

Talk to us about your systems.

Tell us what's held together with workarounds right now. We reply to every message ourselves.