Carpentry and joinery BOQ items: units, measurement, specs
Panelling, storage units, beds, vanities, doors and frames made on site or in a workshop. 6 items, each with the unit it is priced in, how it is measured, the standard that applies, what the line must name and what quotes leave out.
Pujan Motiwala · Standards checked against the BIS catalogue on
Wall panelling
- Unit
- sq ft; also quoted in sq m
- How it is measured
- By face area of panelling; say whether framing and grooves are included. No Indian Standard fixes this for modular work, so the line itself must say it.
- Indian Standards
- IS 1200 (Part 21), Method of measurement of building and civil engineering works: wood-work and joinery; IS 303, Plywood for general purposes.
- The line must name
- Board and its grade: for example IS 303 BWP plywood, IS 710 marine plywood, HDHMR
- Thickness: in mm, for example 18 mm carcass
- Finish: laminate and its thickness, veneer, PU, acrylic, lacquer
- Often left out of the quote
- Backing frame
- Lighting in grooves
- Cut-outs for switches
- A line to start from
- Providing and fixing wall panelling in [12] mm [IS 303 BWP] plywood on [batten] frame, finished in [1] mm laminate; measured by face area including frame.
- Values in [brackets] are yours to fill. Item id: carpentry.panelling
Storage unit (TV, crockery, shoe, study)
- Unit
- sq ft; also quoted in running ft, nos, lump sum
- How it is measured
- Usually by front elevation area (height × width); some quote per unit. State which. No Indian Standard fixes this for modular work, so the line itself must say it.
- Indian Standards
- IS 1200 (Part 21), Method of measurement of building and civil engineering works: wood-work and joinery; IS 303, Plywood for general purposes.
- The line must name
- Board and its grade: for example IS 303 BWP plywood, IS 710 marine plywood, HDHMR
- Thickness: in mm, for example 18 mm carcass
- Finish: laminate and its thickness, veneer, PU, acrylic, lacquer
- Edge band: for example 2 mm PVC edge band
- Hardware make: hinges, channels and fittings by make, or 'or equal'
- Often left out of the quote
- Glass and its frame
- Lights inside
- Handles
- Back panel
- A line to start from
- Providing and making [TV] unit in [18] mm [IS 303 BWP] plywood carcass, [1] mm laminate outside, [0.8] mm laminate inside, [2] mm PVC edge band, [make] soft-close hinges and channels; measured by front elevation area.
- Values in [brackets] are yours to fill. Item id: carpentry.storage-unit
Bed with storage
- Unit
- nos
- How it is measured
- By number, size stated (for example 6 ft × 6.5 ft).
- Indian Standards
- IS 1200 (Part 21), Method of measurement of building and civil engineering works: wood-work and joinery; IS 303, Plywood for general purposes.
- The line must name
- Board and its grade: for example IS 303 BWP plywood, IS 710 marine plywood, HDHMR
- Thickness: in mm, for example 18 mm carcass
- Finish: laminate and its thickness, veneer, PU, acrylic, lacquer
- Hardware make: hinges, channels and fittings by make, or 'or equal'
- Size: a dimension in mm, ft or inches
- Often left out of the quote
- Mattress
- Headboard upholstery
- Side tables
- A line to start from
- Providing and making [6 × 6.5] ft bed in [18] mm [IS 303 BWP] plywood with [hydraulic lift / drawer] storage of [make], finished in [1] mm laminate.
- Values in [brackets] are yours to fill. Item id: carpentry.bed
Bathroom vanity unit
- Unit
- running ft; also quoted in nos
- How it is measured
- By running length or per unit; state which. No Indian Standard fixes this for modular work, so the line itself must say it.
- Indian Standards
- IS 303, Plywood for general purposes; IS 710, Marine plywood.
- The line must name
- Board and its grade: for example IS 303 BWP plywood, IS 710 marine plywood, HDHMR
- Thickness: in mm, for example 18 mm carcass
- Finish: laminate and its thickness, veneer, PU, acrylic, lacquer
- Edge band: for example 2 mm PVC edge band
- Hardware make: hinges, channels and fittings by make, or 'or equal'
- Often left out of the quote
- Counter and basin
- Mirror
- Plumbing connections
- A line to start from
- Providing and making vanity unit in [18] mm [IS 710 marine / IS 303 BWP] plywood, finished in [1] mm laminate, [2] mm PVC edge band, [make] hinges; measured by running length.
- Values in [brackets] are yours to fill. Item id: carpentry.vanity
Flush door shutter
- Unit
- nos; also quoted in sq ft
- How it is measured
- By number with size stated, or by shutter area.
- Indian Standards
- IS 2202 (Part 1), Wooden flush door shutters (solid core type): plywood face panels; IS 1200 (Part 21), Method of measurement of building and civil engineering works: wood-work and joinery.
- The line must name
- Thickness: in mm, for example 18 mm carcass
- Finish: laminate and its thickness, veneer, PU, acrylic, lacquer
- Hardware make: hinges, channels and fittings by make, or 'or equal'
- Often left out of the quote
- Lock and handle
- Door closer and stopper
- Frame (a separate line)
- A line to start from
- Providing and fixing [35] mm flush door shutter to [IS 2202 (Part 1)], finished in [1] mm laminate both sides, with [3] stainless steel hinges of [make].
- Values in [brackets] are yours to fill. Item id: carpentry.flush-door
Door frame
- Unit
- running ft; also quoted in running m, nos
- How it is measured
- By running length of frame, or per door with size stated.
- Indian Standards
- IS 1200 (Part 21), Method of measurement of building and civil engineering works: wood-work and joinery.
- The line must name
- Material: named, for example granite, quartz, AAC block, sal wood
- Size: a dimension in mm, ft or inches
- Often left out of the quote
- Architrave
- Fixing to masonry (hold-fasts)
- A line to start from
- Providing and fixing door frame of [sal wood / WPC] [100 × 60] mm section, including hold-fasts and architrave on [one / both] sides.
- Values in [brackets] are yours to fill. Item id: carpentry.door-frame
Paste a BOQ from Excel and see what each line leaves open, then print it as a quotation.
Designer Ops keeps your own BOQ library and every quote, turns an accepted quote's payment stages into invoices, then runs the project: orders, site visits and the workshop. Try the live demo · system for interior designers · what to require from one
Official sources
- Indian Standards catalogue (Know Your Standards). Bureau of Indian Standards, October 23, 2026.
What this page is not
A guide written by Ahrom Labs; not legal, tax or engineering advice. Indian Standards are cited by number and title from the BIS catalogue, not quoted; the standard governs wherever this page differs from it. No rates are given: they change with city and month. Last updated .
Talk to us about your systems.
Tell us what's held together with workarounds right now. We reply to every message ourselves.